Nominal or standard size, in inches Annealed***
S= 6000 psi 100FS= 5100 psi 150FS= 4900 psi 200FS= 4800 psi 250F
1/41074913877860
3/81130960923904
1/2891758728713
5/8736626601589
3/4852724696682
1655557535524
1-1/4532452434425
1-1/2494420404396
2435370355348
2-1/2398338325319
3385328315308
3-1/2366311299293
4360306294288
5345293281276
6346295283277
8369314301295
10369314301295
12370314302296

Nominal or standard size, in inches Annealed***
S= 4700 psi 300FS= 4000 psi 350FS= 3000 psi 400F
1/4842716537
3/8885753565
1/2698594446
5/8577491368
3/4668568426
1513437327
1-1/4416354266
1-1/2387330247
2341290217
2-1/2312265199
3302257193
3-1/2286244183
4282240180
5270230172
6271231173
8289246184
10289246184
12290247185

Nominal or standard size, in inches Drawn**
S= 10,300 psi 100FS= 10,300 psi 150FS= 10,300 psi 200FS= 10,300 psi 250F
1/41850185018501850
3/81946194619461946
1/21534153415341534
5/81266126612661266
3/41466146614661466
11126112611261126
1-1/4914914914914
1-1/2850850850850
2747747747747
2-1/2684684684684
3662662662662
3-1/2628628628628
4618618618618
5592592592592
6595595595595
8634634634634
10634634634634
12635635635635

Nominal or standard size, in inches Drawn**
S= 10,000 psi 300FS= 9,700 psi 350FS= 9,400 psi 400F
1/4179617421688
3/8188918331776
1/2149014451400
5/8122911931156
3/4142413811338
1109310611028
1-1/4888861834
1-1/2825801776
2726704682
2-1/2664644624
3643624604
3-1/2610592573
4600582564
5575557540
6578560543
8615597578
10615597578
12617598580

* Based on maximum allowable stress in tension (psi) for the indicated temperatures (F).

** When brazing or welding is used to join drawn tube, the corresponding annealed rating must be used.

*** Types M and DWV are not normally available in the annealed temper. Shaded values are provided for guidance when drawn temper tube is brazed or welded. For more information, see Pressure Ratings and Burst Strength.