Nonreinforced Sewer Bell & Spigot

Internal Dia.(in)MIN WALLLB/FT
45/89.5
65/817
83/427
107/837
12150
151-1/480
181-1/2110
211-3/4160
242-1/8200
273-1/4390
303-1/2450
333-3/4520
364580

These tables are based on concrete weighing 150 pounds per cubic foot and will vary with heavier or lighter weight concrete.


Internal Dia.(in)MIN WALLLB/FT
43/413
63/420
87/831
10142
121-3/868
151-5/8100
182160
212-1/4210
243320
273-3/4450
304-1/4540
334-1/2620
364-3/4700

These tables are based on concrete weighing 150 pounds per cubic foot and will vary with heavier or lighter weight concrete.


Internal Dia.(in)MIN WALLLB/FT
47/815
6124
81-1/836
101-1/450
121-3/490
151-7/8120
182-1/4170
212-3/4260
243-3/8350
273-3/4450
304-1/4540
334-1/2620
364-3/4700

These tables are based on concrete weighing 150 pounds per cubic foot and will vary with heavier or lighter weight concrete.